The instruments are
suitable for the ion contamination levels testing of bare PCB board as well as
PCBA before and after cleaning and coating processes.
FEATURES
(1)Precise
Adopting online high-precision conductivity meter, fully enclosed
circulatory system, mixed anion and cation exchange resins, as well as real-time
processing algorithms and temperature compensation technology.
(2)Efficient
Adopting heat extraction and high-speed loop flushing technology.
(3)Characteristic
Unique dynamic / static test mode.
(4)Customize
Volume can be customized according to the requirements.
USAGE
The instruments are suitable for the ion contamination levels testing of bare PCB board as well as PCBA before and after cleaning and coating processes.
FEATURES
(1)Precise
Adopting online high-precision conductivity meter, fully enclosed circulatory system, mixed anion and cation exchange resins, as well as real-time processing algorithms and temperature compensation technology.
(2)Efficient
Adopting heat extraction and high-speed loop flushing technology.
(3)Characteristic
Unique dynamic / static test mode.
(4)Customize
Volume can be customized according to the requirements.
SPECIFICATIONS
Item
LZ22A
Test Method
Static/Dynamic testing
Volume of Water Tank
680mm×65mm×680mm(L×W×H) about 30L
Machine Size
1401mm×600mm×1000mm(L×W×H)
Test size
10 CM × 40 CM ~68 CM × 68 CM
Power
1700W
Machine Weight
180Kg
Test Accuracy
±5%
Resolution of Conductivity
0.001us/cm2
Electrode Resolution Range
0.0001us/cm2~20 us/cm2 (NaCl:300 ~ 100000 ug )
Measuring Circuit Board Area
1200-8712cm2
Proportion of Extract
0.85~0.855
Reference
66/100MΩ
Power Requirement
AC220V 50HZ
Working Environment Temperature
22℃±15℃
Efficiency
5~15 minutes every time
Working Extract Temperature
40℃±2℃
Life of the filter
≤0.12 us/cm -16000pcs
IPA Loss
Test 30 pcs-1L
The heating Efficiency
40℃±2℃ ~ 15-25 Min