Ionic Contamination Tester LZ22


USAGE

 

The instruments are suitable for the ion contamination levels testing of bare PCB board before and after cleaning and coating processes as well as PCBA before and after the

cleaning process.

 

FEATURES

 

(1)Precise

Adopting online high-precision conductivity meter, fully enclosed circulatory system, mixed anion and cation exchange resins, as well as real-time processing algorithms and temperature compensation technology.

 

(2)Efficient

Adopting heat extraction and high-speed loop flushing technology.

 

(3)Characteristic

Unique dynamic / static test mode.

 

(4)Customize

Volume can be customized according to the requirements.       


SPECIFICATIONS



Item

LZ22

Test Method

Static/Dynamic testing

Volume of Water Tank

352mm×70mm×600mm(L×W×H) about 15L

Test the size

10cm*20cm-35cm*60cm

Test size

10 CM × 20 CM ~35 CM × 60 CM

Power

1300W

Test Accuracy

±5%

Resolution of Conductivity

0.001us/cm2

Electrode Resolution Range

0.0001us/cm2~20 us/cm2 (NaCl:300 ~ 100000 ug )

Measuring Circuit Board Area

800-4200cm2

Proportion of Extract

0.85~0.855

Reference

66/100

Power Requirement

AC220V 50HZ

Working Environment Temperature

22℃±15

Efficiency

515 minutes every time

Working Extract Temperature

40℃±2℃

Life of  the filter

≤0.12 us/cm -16000pcs

IPA Loss

Test 30 pcs-1L

The heating Efficiency

40℃±2℃ ~ 15-25 Min

Machine Size

1050mm×600mm×920mm(L×W×H)

Machine Weight

115Kg



  • Mobile | PC version | Client Top